Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12984/3677
Full metadata record
DC FieldValueLanguage
dc.creatorMartínez-García, Ricardo Adolfo-
dc.creatorEspinosa-Solares, Teodoro-
dc.creatorFlores-Velázquez, Jorge-
dc.creatorRojano-Aguilar, Abraham-
dc.creatorReséndiz-Cantera, Omar-
dc.creatorArzeta-Ríos, Abraham Jesús-
dc.date2019-10-18-
dc.identifierhttps://biotecnia.unison.mx/index.php/biotecnia/article/view/1125-
dc.identifier10.18633/biotecnia.v22i1.1125-
dc.descriptionLa digestión anaeróbica de residuos de explotacionespecuarias presenta beneficios tales como, la reducción de olores y agentes patógenos, la producción de biogás y biofertilizantes. La producción de metano está influenciada, entre otros factores, por el desempeño hidrodinámico del digestor. El objetivo de esta investigación fue construir y validar un modelo numérico basado en Dinámica de Fluidos Computacional (CFD), a partir de un prototipo de un digestor anaeróbico de laguna cubierta. Las simulaciones del modelo en CFD fueron realizadas a partir de las características del reactor y las propiedades del fluido de trabajo. Para comprobar la concordancia del modelo, los resultados numéricos se relacionaron con datos experimentales generados mediante Velocimetría de Imágenes de Partículas (PIV) en un modelo a escala del digestor original. Con el modelo validado, se simularon cuatro alternativas de diseño. Los resultados mostraron mayor eficiencia del patrón de flujo al incluir recirculación. La reducción de espacio muerto entre configuraciones propuestas con respecto al original osciló entre 12,7-19,2%. La configuración de mejor desempeño hidrodinámico fue con recirculación de 2/3 de la alimentación en la entrada original y el otro tercio la distancia de 12 m y con un ángulo de 90° respecto a la línea de entrada.ABSTRACTAnaerobic digestion of livestock waste has benefits such as reduction of odours and pathogens, production of biogas and biofertilizers. Methane production is influenced, among other factors, by the hydrodynamic performance of the digester. The objective of this research was to construct and validate a numerical model based on Computational Fluid Dynamics (CFD), from a prototype of a covered lagoon anaerobic digester. CFD model simulations were performed from reactor characteristics and working fluid properties. To check the agreement of the model, the numerical results were related to experimental data generated by Particle Imaging Velocimetry (PIV) in a scale model of the original digester. With the validated model, four design alternatives were simulated. The results showed greater efficiency of the flow pattern by including recirculation. The reduction in dead space between proposed configurations with respect to the original, ranged from 12.7-19.2%. The best hydrodynamic performance configuration was with recirculation of 2/3 of the feed at the original inlet and the other third at 12 m and at an angle of 90° to the input line.es-ES
dc.formatapplication/pdf-
dc.formattext/xml-
dc.languagespa-
dc.publisherUniversidad de Sonoraes-ES
dc.relationhttps://biotecnia.unison.mx/index.php/biotecnia/article/view/1125/363-
dc.relationhttps://biotecnia.unison.mx/index.php/biotecnia/article/view/1125/409-
dc.rightsDerechos de autor 2019 Biotecniaes-ES
dc.sourceBiotecnia; Vol. 22 No. 1 (2020); 56-66en-US
dc.sourceBiotecnia; Vol. 22 Núm. 1 (2020); 56-66es-ES
dc.source1665-1456-
dc.source1665-1456-
dc.subjectPIVes-ES
dc.subjectmodelo a escalaes-ES
dc.subjectespacio muertoes-ES
dc.subjectMezcladoes-ES
dc.subjectdigestiónes-ES
dc.titleMejoramiento del desempeño hidrodinámico de un digestor anaeróbico de laguna cubierta mediante CFD//Improving the hydrodynamic performance of a covered lagoon anaerobic digester by CFDes-ES
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/publishedVersion-
Appears in Collections:REVISTA BIOTECNIA
Show simple item record

Page view(s)

54
checked on Jun 22, 2023

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.