Title: ESTIMACIÓN DE LA INCERTIDUMBRE EN LA CUANTIFICACIÓN DE FÓSFORO POR ESPECTROFOTOMETRÍA ULTRAVIOLETA-VISIBLE/ UNCERTAINTY ESTIMATION IN THE PHOSPHORUS QUANTIFICATION BY ULTRAVIOLET-VISIBLE SPECTROPHOTOMETRY
Authors: 
Keywords: Fósforo; espectrofotometría UV/Vis; incertidumbre expandida; refrescos de cola/ Phosphorus; spectrophotometry UV/Vis; expanded uncertainty; cola drink.
Publisher: Universidad de Sonora
Description: La incertidumbre es un parámetro no negativo asociado al resultado de una medición, que caracteriza la dispersión de los valores que podrían razonablemente, atribuirse a una magnitud particular sometida a medición (mensurando). El objetivo de este trabajo fue estimar la incertidumbre de un método analítico validado para cuantificar fósforo mediante espectrofotometría UV-Visible. Se establecieron las fuentes de incertidumbre elaborando un diagrama de Ishikawa (causa- efecto). Posteriormente se estimaron las incertidumbres, entre las cuales se encuentra la incertidumbre de la masa considerando la curva de calibración, masa, pureza, masa molar, factor de dilución y la concentración del mensurando. A partir de estos datos se estimó la incertidumbre estándar combinada (uCP= 1.506 mgL-1), la incertidumbre estándar relativa (urcp = 1.331 x 10-2) y la incertidumbre expandida (UCP = 3.01 mgL-1). En el proceso de validación del método analítico se cuantificó la concentración de fósforo en un refresco de cola, por lo que a ese valor se debe agregar el resultado de la incertidumbre expandida (UCP). Por lo tanto, el resultado final fue 113.15 ± 3.01 mgL-1 de fósforo. ABSTRACT Uncertainty is a non-negative parameter associated with the result of a measurement that characterizes dispersion of the values that could reasonably be attributed to a particular magnitude subjected to measurement (measurand). The objective of this study was to estimate the uncertainty of a validated analytical method to quantify phosphorus in a cola beverage, using UV-Visible spectrophotometry. The sources of uncertainty were estimated with an Ishikawa diagram (cause-effect). Subsequently, the uncertainties were estimated, among which the mass uncertainty is, considering the calibration curve , weight, purity, molar mass, dilution factor and the concentration of the measurand. From these data, the combined standard uncertainty (uCP = 1.506 mgL-1), the relative standard uncertainty (urcp = 1.331 x 10-2) and the expanded uncertainty (UCP = 3.01 mgL-1) were estimated. In the process of validation of the analytical method, the phosphorus concentration in a cola drink was quantified, so that expanded uncertainty (UCP) value should be added to the results. Therefore, the final result was 113.15 ± 3.01 mg L-1 of phosphorus
URI: http://hdl.handle.net/20.500.12984/3765
Other Identifiers: https://biotecnia.unison.mx/index.php/biotecnia/article/view/232
10.18633/bt.v17i3.232
Appears in Collections:REVISTA BIOTECNIA

Show full item record

Page view(s)

66
checked on Jun 22, 2023

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.